General specifications | ||
---|---|---|
Measuring method | Level control with ceramic measuring cell (dry measuring cell). The pressure acts directly on the rugged ceramic membrane of the LGC level probe and causes it to move by about max. 0.005 mm. The effects of air pressure on the liquid surface are transferred via a pressure compensating tube through the extension cable to the rear of the ceramic membrane and compensated. Pressure-dependent changes in capacitance caused by membrane movement are measured at the electrodes of the ceramic carrier. The electronics convert the movement into a pressure-proportional signal which is linear to the medium level. |
|
Equipment architecture | The measuring system consists of a LGC level probe and a SMART transmitter power supply (e. g. KFD2-STC4-Ex1) with a supply voltage between 10 ... 30 V DC. |
|
Construction type | device with rod probe | |
Supply | ||
Rated voltage | LGC: 10 ... 30 V DC, Ex nA and Ex ia: 10 ... 30 V DC Pt100 (optional): 10 ... 30 V DC, Ex nA: 10 ... 30 V DC temperature transmitter (optional): 8 ... 35 V DC |
|
Current consumption | LGC: max. ≤ 22.5 mA, min. ≥ 3.5 mA Pt100 (optional): ≤ 0.6 mA temperature transmitter (optional): Pt100 via temperature transmitter ≤ 0.6 mA |
|
Reverse polarity protection | Reverse voltage protection is integrated in LGC level probe and in the temperature transmitter LGC-Z13 changing the polarities has no impact on operation. | |
Residual ripple | LGC: 4 ... 20 mA for hydrostatic pressure measured value, two-wire Pt100 (optional): temperature-dependent resistance of Pt100 temperature transmitter (optional): 4 ... 20 mA for temperature measured value, two-wire |
|
Input | ||
Input signal | LGC: change in capacitance Pt100 (optional): change in resistance temperature transmitter (optional): Pt100 resistance signal, 4-wire |
|
Measured variable | LGC: hydrostatic pressure of a liquid Pt100 (optional): temperature of a liquid temperature transmitter (optional): temperature |
|
Measurement range | LGC: - nine fixed pressure measuring ranges in bar, see ordering information - customer-specific measuring ranges, factory-calibrated Pt100 (optional): temperature measurement from -10 ... 70 °C (263 ... 343 K) |
|
Output | ||
Output signal | LGC: 4 ... 20 mA for hydrostatic pressure measured value, two-wire Pt100 (optional): temperature-dependent resistance of Pt100 temperature transmitter (optional): 4 ... 20 mA for temperature measured value, two-wire |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529:2001 | |
Measurement accuracy | ||
Reference operating conditions | LGC, Pt100 (optional): acc. to DIN EN 60770, Tamb = 25 °C (296 K) temperature transmitter (optional): calibration temperature 23 °C ± 5 K (296 K ± 5 K) |
|
Accuracy | LGC: non-linearity including hysteresis and non-repeatability as per DIN EN 60770: ± 0.2 % of upper range value (URV) Pt100 (optional): max. ± 0.7 K (class B to DIN EN 60751) temperature transmitter (optional): ± 0.2 K, with Pt100: max. ± 0.9 K |
|
Long-term drift | LGC, Pt100 (optional): ± 0.1 % of upper range value (URL) per year temperature transmitter (optional): ± 0.1 K per year |
|
Influence of medium temperature | - thermal change in zero signal and output span for typical temperature range 0 ... 30 °C (273 ... 303 K): ± 0.4 % (± 0.5 %)* of the measuring span - thermal change in zero signal and output span for the total medium temperature range -10 ... 70 °C (263 ... 343 K): ± 1.0 % (± 1.5 %)* of the measuring span (Pt100) - temperature coefficient (TK) in zero signal and output span: 0.15 %/10 K (0.3 %/10 K)* of the measuring span (Pt100 and temperature transmitter) *specifications for sensors 0.1 bar and 0.6 bar |
|
Rise time | LGC: 80 ms, Pt100 (optional): 160 s | |
Warm-up time | LGC, Pt100 (optional): 20 ms, temperature transmitter (optional): 4 s | |
Adjustment time | LGC: 150 ms, Pt100 (optional): 300 s | |
Operating conditions | ||
Installation conditions | ||
Installation position | vertical from above | |
Process conditions | ||
Medium temperature | LGC, Pt100 (optional): -10 ... 70 °C (263 ... 343 K), for Ex devices see safety information temperature transmitter (optional): -40 ... 85 °C (233 ... 358 K) = ambient temperature, install temperature transmitter outside medium |
|
Medium temperature limits | LGC, Pt100 (optional): -20 ... 70 °C (253 ... 343 K) You may operate the LGC in this temperature range. The specification can then be exceeded, e.g. measuring accuracy, see also DIN 16086. |
|
Ambient conditions | ||
Ambient temperature | LGC, Pt100 (optional): -10 ... 70 °C (263 ... 343 K) = medium temperature temperature transmitter (optional): -40 ... 85 °C (233 ... 358 K) |
|
Storage temperature | LGC, Pt100 (optional): -40 ... 80 °C (233 ... 353 K) temperature transmitter (optional): -40 ... 100 °C (233 ... 373 K) |
|
Mechanical specifications | ||
Degree of protection | LGC, Pt100 (optional): IP68, permanently hermetically sealed, optional terminal box IP66/IP67 temperature transmitter (optional): IP00, moisture condensation permissible, when mounted in the optional terminal boxes IP66/IP67 |
|
Connection | 3 terminals in terminal housing as standard 4 terminals in block, accessories LGC-Z15 for conductor cross section 0.08 ... 2.5 mm2 |
|
Material | level probe LGC: 1.4435/316L process ceramic: Al2O3 aluminum oxide ceramic seal (internal): EPDM or Viton protective cap: PE-HD (high-density polyethylene) terminal box LGC-Z11: PC (polycarbonate) temperature transmitter LGC-Z13: housing PC (polycarbonate) extension cable PE: insulation PE (polyethylene), copper wires, twisted extension cable FEP: insulation FEP (fluorinated ethylene propylene), copper wires, twisted |
|
Cable | LGC: - commercially available instrument cable - terminals, terminal housing LGC: 0.08 ... 2.5 mm2 Pt100 (optional): - If the Pt100 signal is directly connected to a display and/or evaluation unit, we recommend the use of a shielded cable. temperature transmitter (optional): - connection transmitter: max. 1.75 mm2 extension cable: - total outer diameter: 8.0 mm ± 0.25 mm (0.315 inch ± 0.0098 inch) - LGC: 3 x 0.227 mm2 and pressure compensation tube with PTFE filter - Pt100 (optional): 7 x 0.227 mm2 and pressure compensation tube with PTFE filter - pressure compensation tube with PTFE filter: outer diameter Ø2.5 mm (0.098 inch), internal diameter Ø1.5 mm (0.059 inch) |
|
Mass | level probe LGC: 290 g terminal box LGC-Z11: 235 g temperature transmitter LGC-Z13: 40 g extension cable PE: 52 g/m extension cable FEP: 108 g/m suspension clamp LGC-Z10: 170 g extension cable mounting screw LGC-Z14: 770 g extension cable mounting screw LGC-Z16: 724 g |
|
Dimensions | level probe LGC: Ø22 x 240 mm (Ø0.9 x 9.5 inch) terminal housing LGC-Z11: 120 x 80 x 55 mm (4.7 x 3.15 x 2.2 inch) temperature transmitter LGC-Z13: Ø44 x 21 mm (1.7 x 0.8 inch) extension cable: 10 m (33 ft), 20 m (66 ft) or any length, can be cropped - max. free suspended length (mechanical stability under load): 1000 m (3294 ft) - max. length for non-Ex and EEx nA IIC T6, see section load - max. length for EEx ia IIC T6: see related safety information (SI) |
|
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | TÜV 01 ATEX 1749 | |
Group, category, type of protection, temperature class | II 2G Ex ia IIC T6 Gb | |
Statement of conformity | PF 16 CERT 1658 X | |
Group, category, type of protection, temperature class | II 3G Ex nA IIC T6 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2007 , EN 60079-15:2010 | |
Certificates and approvals | ||
Drinking water approval | KTW certificate and NSF approval | |
Accessories | ||
Optional accessories | LGC-Z10 mounting clamp, 1.4435/316L LGC-Z11, terminal box (IP65/IP67), PC LGC-Z12, additional weight 300 g, 1.4435/316L LGC-Z13, temperature transmitter, 2-wire, -20 ... 80 °C LGC-Z14, cable mounting screw G with cylindrical threading G1-1/2A, 1.4301/304 LGC-Z15, terminal block with 4 terminals LGC-Z16, cable mounting screw N with tapered thread NPT1-1/2, 1.4301/304 |
System | Classcode |
---|---|
ECLASS 13.0 | 27200516 |
ECLASS 12.0 | 27200516 |
ECLASS 11.0 | 27200516 |
ECLASS 10.0.1 | 27200516 |
ECLASS 9.0 | 27200516 |
ECLASS 8.0 | 27200516 |
ECLASS 5.1 | 27200516 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC001447 |
ETIM 7.0 | EC001447 |
ETIM 6.0 | EC001447 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
Literature | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
Product information Level probe LGC | ENG | 93 KB |
Safety and Security Documentation | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
SD126O, Instruction manual LGC / SD126O, Betriebsanleitung LGC | ALL | 136 KB | |
SI131O-A, Instruction manual LGC / SI131O-A, Betriebsanleitung LGC | ALL | 930 KB | |
SI132O-A, Instruction manual LGC / SI132O-A, Betriebsanleitung LGC | ALL | 260 KB | |
Manuals | |||
Manual LGC | ENG | 904 KB |
Certificates | Número de Certificado | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|---|
CSA Control Drawing | ZD064O-A | ALL | 50 KB | |
Canada CSA | CoC 212978 | ALL | 251 KB | |
Europe Pepperl+Fuchs | SD1260 | ALL | 32 KB | |
FM Control Drawing | ZD063O-A | ALL | 62 KB | |
USA FM | CoC 3012697 | ALL | 81 KB | |
Control Drawings | ||||
Control drawing CSA / Control drawing CSA | ALL | 15 KB | ||
ZD063O, Control drawing FM, LGC | ENG | 160 KB | ||
ZD064O, Control drawing CSA, LGC | ENG | 132 KB | ||
Contamination Declaration | ||||
Contamination declaration / Kontaminationserklärung | ALL | 137 KB |